top of page

Scale-up Systems
Customized Inclusions and Layout to Meet Requirements

3000kg/hour input biochar system
2000kg/hour input biochar system
3000kg/hour input biochar system

Data Summary (under general assumption) – 3,000kg/h System

  1. 3 x 1,000kg/h biochar system with a total handling capacity 3,800 kg / hour raw feedstock input at 25% moisture content (MC).

  2. More than 27,300 tons annual raw feedstock handling capacity (based on annually work 7,200 hours, and the material moisture content up to 25%)

  3. With the fit for purpose designed front drying system, the biochar yield improves approximately by approximate 12%.

  4. The system has designed capacity to annually produce dry biochar approximately 7,200 tonnes (0% MC), or approximately 9,000 tonnes at moisture content around 20%.

  5. A smaller portion of the heat from pyrolysis is used for raw biomass material pre-heating and drying prior to pyrolysis for making biochar, and

  6. A larger portion of the heat from pyrolysis can be used for electricity generation (using ORC system) if this is the choice of utilizing the heat. The electricity output is approximately between 220-260kWh.

  7. Total equipment installed power: 261kw; Actual effective average power consumption: 174kw/h.

bottom of page